Conduit transition fitting for flexible corrugated plastic (KRFG) conduits

Conduit transition fitting for flexible corrugated plastic (KRFG) conduits

The transition fitting for KRFG conduits accepts either an M20 or an M25 conduit (n the same entry) and anchors it securely against being pulled out. When inserting conduits into the fitting from beneath the ceiling, the non-concentric entry hole for the M20 conduit enables conduits of both sizes - M20 or M25 - to be kept close to the wall as they enter the fitting.
  • Only one article (item) for conduit sizes 20/25 mm - flush-mounted / surface-mounted
  • Optimal in the case of heavy reinforcement
  • Wall-mounted conduits - either 20 mm or 25 mm - can be inserted without an offset from the wall

Installation

Nail the conduit transition fitting at the wall/ceiling transition using pre-inserted nails.
Nail the conduit transition fitting at the wall/ceiling transition using pre-inserted nails.
Conduits of size M20 ...
Conduits of size M20 ...
... and M25 can be inserted into the same combi-entry.
... and M25 can be inserted into the same combi-entry.
The conduit may be additionally secured by fixing with tying wire to the projection on the fitting.
The conduit may be additionally secured by fixing with tying wire to the projection on the fitting.
Even in the case of heavy reinforcement, the conduit is routed above the rebar.
Even in the case of heavy reinforcement, the conduit is routed above the rebar.
A two-part stopper seals the opening reliably.
A two-part stopper seals the opening reliably.
To insert an M20 conduit, remove the (non-concentric) inner part of the stopper using a screwdriver.
To insert an M20 conduit, remove the (non-concentric) inner part of the stopper using a screwdriver.
Appearance after removing the inner part of the stopper for an M20 conduit.
Appearance after removing the inner part of the stopper for an M20 conduit.
An M20 conduit can then be inserted without an offset from the wall.
An M20 conduit can then be inserted without an offset from the wall.
To insert an M25 conduit, remove the entire stopper including the outer ring.
To insert an M25 conduit, remove the entire stopper including the outer ring.
Appearance after removing the entire stopper including outer ring for an M25 conduit.
Appearance after removing the entire stopper including outer ring for an M25 conduit.
An M25 conduit can then be inserted without an offset from the wall.
An M25 conduit can then be inserted without an offset from the wall.

Installation

Nail the conduit transition fitting at the wall/ceiling transition using pre-inserted nails.
Nail the conduit transition fitting at the wall/ceiling transition using pre-inserted nails.
Conduits of size M20 ...
Conduits of size M20 ...
... and M25 can be inserted into the same combi-entry.
... and M25 can be inserted into the same combi-entry.
The conduit may be additionally secured by fixing with tying wire to the projection on the fitting.
The conduit may be additionally secured by fixing with tying wire to the projection on the fitting.
Even in the case of heavy reinforcement, the conduit is routed above the rebar.
Even in the case of heavy reinforcement, the conduit is routed above the rebar.
A two-part stopper seals the opening reliably.
A two-part stopper seals the opening reliably.
To insert an M20 conduit, remove the (non-concentric) inner part of the stopper using a screwdriver.
To insert an M20 conduit, remove the (non-concentric) inner part of the stopper using a screwdriver.
Appearance after removing the inner part of the stopper for an M20 conduit.
Appearance after removing the inner part of the stopper for an M20 conduit.
An M20 conduit can then be inserted without an offset from the wall.
An M20 conduit can then be inserted without an offset from the wall.
To insert an M25 conduit, remove the entire stopper including the outer ring.
To insert an M25 conduit, remove the entire stopper including the outer ring.
Appearance after removing the entire stopper including outer ring for an M25 conduit.
Appearance after removing the entire stopper including outer ring for an M25 conduit.
An M25 conduit can then be inserted without an offset from the wall.
An M25 conduit can then be inserted without an offset from the wall.

Dimensions / Form

Product length:
61 mm
Product width:
78 mm
Product depth:
75 mm

Connections / Entries

For conduit Ø:
20 mm, 25 mm

Assembly / Installation

Assembly type:
BB (solid construction)

Safety / Properties

Special application:
on-site mixed concrete