Ceiling box HWD 30

recommendations

Ceiling box HWD 30
Artikel-No. 9463-50
E-No 372632019
  • for fire protection ceilings F30-F90 or EI30-EI90
  • For F30 (EI30) non-insulated fire-protection ceilings
  • For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
  • for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100
Ceiling junction box HWD 30
Artikel-No. 9464-50
E-No 372632029
  • for fire protection ceilings F30-F90 or EI30-EI90
  • For F30 (EI30) non-insulated fire-protection ceilings
  • For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
  • for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100

Ceiling box HWD 30

HWD 30 ceiling box guarantees F30 (EI30) to F90 (EI90) fire protection. If a fire starts, the integrated fire-retardant coating immediately generates foam and seals the opening in the ceiling. Even when retrofitted, the HWD30 ceiling box provides protection.
  • For F30-F90 or EI30-EI90 fire protection ceilings
  • Encasing is not necesssary
  • For installation of smoke detectors, motion detectors, etc.
  • With a fire-protection cover, can be used as a ceiling junction box
  • Retrofitting also possible

Installation

Cut installation opening using the PROFI cutting head (art. no. 1081-21) incl. dust extraction (art. no. 1088-50).
Cut installation opening using the PROFI cutting head (art. no. 1081-21) incl. dust extraction (art. no. 1088-50).
Cut the exact opening for the cable with the KAISER universal opening cutter.
Cut the exact opening for the cable with the KAISER universal opening cutter.
Fixing of the boxes with tried-and-tested cavity wall technology using KAISER FX⁴ technology.
Fixing of the boxes with tried-and-tested cavity wall technology using KAISER FX⁴ technology.
The fire-protection cover for F30 ceilings has fire resistance class F30, for F90 ceilings it has fire resistance class F90.
The fire-protection cover for F30 ceilings has fire resistance class F30, for F90 ceilings it has fire resistance class F90.

Assembly / Installation

Assembly type:
HW (drywall/lightweight construction), hollow ceiling

Safety / Properties

Halogen-free:
Yes
Special application:
Fire protection

Approvals / Certifications

fire resistance class:
EI 30, EI 60, EI 90, EI 120, F 30, F 60, F 90, F 120
DIBT approval:
Z-19.21-1788
VDE:
Yes
Ceiling box HWD 30
Artikel-No. 9463-50
E-No 372632019
  • for fire protection ceilings F30-F90 or EI30-EI90
  • For F30 (EI30) non-insulated fire-protection ceilings
  • For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
  • for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100
Ceiling junction box HWD 30
Artikel-No. 9464-50
E-No 372632029
  • for fire protection ceilings F30-F90 or EI30-EI90
  • For F30 (EI30) non-insulated fire-protection ceilings
  • For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
  • for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100