Mini equipment carrier

tools

SPECIAL cutter ETICS Ø 20 x 80 mm
Artikel-No. 1088-06
E-No 983228006
  • Making installation openings in existing composite thermal insulation systems or lightweight walls
  • Ø 20 mm, for the KAISER mini equipment carrier and for KAISER cable seals
  • with depth stop to prevent heat bridges
  • with hardened metal centering drill for precise positioning
  • fits all battery-powered drills and electric drills with 10 mm chuck
  • removable cutter head for easy removal of the drilled core

Mini equipment carrier

Mini equipment carrier for later attachment of a variety of accessories to insulated and already plastered composite thermal insulation systems (ETICS). Luminaires, motion detectors, external sensors etc. can be permanently attached easily, quickly, securely and without creating heat bridges.
  • For retrofitting in insulated facades
  • Exact flush aligning of attachment devices
  • Guarantees installation without heat bridges
  • 4 swivels for secure anchoring
  • No moisture penetration

Examples of use

The small mini device carriers are concealed by luminaires and smaller accessories.
The small mini device carriers are concealed by luminaires and smaller accessories.
Secure attachment of motion detectors.
Secure attachment of motion detectors.
Invisible even when close to edges.
Invisible even when close to edges.
Secure, easy fitting of the corner mounting.
Secure, easy fitting of the corner mounting.

Heat bridge calculation

A heat bridge analysis produced by the Passivhaus Institut Dr. Feist, Darmstadt, showed that heat conductivity is only changed to a negligible extent and consequently it is demonstrated that there are no heat bridges in the electrical installation. The loss coefficient "× WB" is 0.000054 W/K.
Heat bridge calculation

Maximum pull-out force for the mini equipment carrier.

Maximum pull-out force for the mini equipment carrier.
(1) External insulation - insulation thickness

Structure of an organic ETICS

The mini equipment carrier was developed especially for later installation in organic composite thermal insulation systems (ETICS).
Structure of an organic ETICS
(1) Masonry wall | (2) Adhesive | (3) Insulating board | (4) Reinforcement plaster | (5) Reinforcement fabric | (6) Reinforcement plaster | (7) Finish coat of plaster, decorative plaster

Technical information

The swivels anchor the KAISER mini equipment carrier in the insulation.
The swivels anchor the KAISER mini equipment carrier in the insulation.
Clamping ribs, sealing lip and holding ring provide additional stability.
Clamping ribs, sealing lip and holding ring provide additional stability.
The adjustable screw-on surface accommodates a tolerance of up to 10 mm.
The adjustable screw-on surface accommodates a tolerance of up to 10 mm.
The screw-on surface is concealed even when the attachment points are close to the edge.
The screw-on surface is concealed even when the attachment points are close to the edge.

Installation

The two-piece mini equipment carrier can be anchored securely in the insulated external facade in a few simple steps.
Create installation openings of Ø 20 mm with SPECIAL cutter with depth stop (Art. No. 1088-06).
Create installation openings of Ø 20 mm with SPECIAL cutter with depth stop (Art. No. 1088-06).
Release the cutter head and remove the drilled core.
Release the cutter head and remove the drilled core.
Press the anchor sleeve of the mini equipment carrier into the installation opening so that it is flush with the wall.
Press the anchor sleeve of the mini equipment carrier into the installation opening so that it is flush with the wall.
Press in the attachment core until it locks into the anchor sleeve.
Press in the attachment core until it locks into the anchor sleeve.
Pressing in the attachment core anchors the swivels in the insulation material and provides a secure fit for the mini equipment carrier.
Pressing in the attachment core anchors the swivels in the insulation material and provides a secure fit for the mini equipment carrier.
The mini equipment carriers now provide stable and wall-flush screw-on surfaces...
The mini equipment carriers now provide stable and wall-flush screw-on surfaces...
…and provide a tolerance compensation of up to 10 mm. This permits later exact alignment of all installation accessories.
…and provide a tolerance compensation of up to 10 mm. This permits later exact alignment of all installation accessories.
The luminaire is securely and permanently flush-mounted to the wall.
The luminaire is securely and permanently flush-mounted to the wall.

Dimensions / Form

Product length:
60 mm
Installation opening (wall/ceiling) length:
Ø20 mm
Installation opening (wall/ceiling) width:
Ø20 mm
Cover for box/housing/casing Ø:
Ø20 mm

Assembly / Installation

Assembly type:
ETICS/external insulation

Safety / Properties

Halogen-free:
Yes
Certificate

Heat bridge calculation - Test report

801.9 KB | 08/11/2019
SPECIAL cutter ETICS Ø 20 x 80 mm
Artikel-No. 1088-06
E-No 983228006
  • Making installation openings in existing composite thermal insulation systems or lightweight walls
  • Ø 20 mm, for the KAISER mini equipment carrier and for KAISER cable seals
  • with depth stop to prevent heat bridges
  • with hardened metal centering drill for precise positioning
  • fits all battery-powered drills and electric drills with 10 mm chuck
  • removable cutter head for easy removal of the drilled core