ThermoX® installation housing

accessories

ThermoX® individual front rings
Artikel-No. 9300-43
  • for retrofitting or as spare part
ThermoX® universal front ring
Artikel-No. 9300-93
  • for retrofitting or as spare part
  • Universal front ring
ThermoX® Decorative coverings
Artikel-No. 9301-11
E-No 920829119
  • metal with galvanised or powder coating
  • only for interiors
  • minimum diameter of the luminaire 79 mm with ceiling exit Ø 68 and 75 mm
  • Minimum diameter of luminaire covering 86 mm with ceiling exit Ø 82 mm
ThermoX® Decorative coverings
Artikel-No. 9301-13
E-No 920829319
  • metal with galvanised or powder coating
  • only for interiors
  • minimum diameter of the luminaire 79 mm with ceiling exit Ø 68 and 75 mm
  • Minimum diameter of luminaire covering 86 mm with ceiling exit Ø 82 mm

similar

ThermoX® housing for low and high-voltage luminaires
Artikel-No. 9300-01
E-No 920849409
  • for halogen luminaires and pivoting LED luminaires
  • max. installation height for low-voltage luminaire 65 mm, HV luminaire 70 mm
  • Heat distortion resistant to 220°C
  • lamp wattage LV: max. 35 W with AL reflector / 20 W Cool-Beam
  • lamp wattage for HV luminaires max. 35 W with AL reflector (socket GU 10)
  • max. LED lamp output 6.6 W
  • Front can be used on both sides
ThermoX® housing for low and high-voltage luminaires
Artikel-No. 9300-02
E-No 920849419
  • for halogen luminaires and pivoting LED luminaires
  • max. installation height for low-voltage luminaire 65 mm, HV luminaire 70 mm
  • Heat distortion resistant to 220°C
  • lamp wattage LV: max. 35 W with AL reflector / 20 W Cool-Beam
  • lamp wattage for HV luminaires max. 35 W with AL reflector (socket GU 10)
  • max. LED lamp output 6.6 W
  • Front can be used on both sides

ThermoX® installation housing

ThermoX® installation housing for installing halogen and pivoting recessed LED luminaires in various ceiling structures. The housing protects the surrounding material (moisture barrier foil, insulation etc.) from the lamp's extreme operating temperatures and creates an air-tight closure.
  • Installation housing for halogen luminaires (low voltage and high voltage)
  • Fire-preventive and air-tight
  • For insulated hollow ceilings
  • Two different front part types
  • Integrated transformer closing cap
  • Ceiling exits (CE) up to Ø 86 mm
  • Installation from either above or below

Installation technology for low-voltage and high-voltage luminaires

Usable lamps: Cool-Beam max. 20 W, aluminium reflector max. 35 W
Luminaire selection: halogen, low-voltage (12 V)
Usable lamps: Cool-Beam max. 20 W, aluminium reflector max. 35 W
Aluminium reflector 35 W
Temperature profile: room temperature (23 °C)
Aluminium reflector 35 W
Usable lamps: Cool-Beam max. 20 W, aluminium reflector max. 35 W
Luminaire selection: halogen, high-voltage (230 V)
Usable lamps: Cool-Beam max. 20 W, aluminium reflector max. 35 W
Aluminium reflector 35 W
Temperature profile: room temperature (23 °C)
Aluminium reflector 35 W
Usable lamps with "x": Cool-Beam max. 35 W, aluminium reflector max. 50 W
Luminaire selection: halogen (12 V / high-voltage 230 V) x = min. 50 mm
Usable lamps with "x": Cool-Beam max. 35 W, aluminium reflector max. 50 W
Aluminium reflector 50 W
Temperature profile: halogen, low voltage (12 V)
Aluminium reflector 50 W
Aluminium reflector 50 W
Temperature profile, halogen, high voltage (230 V)
Aluminium reflector 50 W
up to 6.6 W / ET max. 70 mm
Use of pivoting LED built-in luminaires
up to 6.6 W / ET max. 70 mm

Slab ceiling / Installation from above: during ceiling installation

Cut the installation opening and insert the housing from above. The shape of the front part ensures a secure and precise fit in the boarding. After the luminaire has been installed, the opening is completely concealed.

Slab ceilings / Installation from below: retrofitting

Cut an installation opening, insert the housing from below and fix in place with a fast screw attachment. The housing is attractively concealed by the KAISER decorative covering and the luminaire.

Plasterboard / Installation from below: retrofitting / smoothing

Before installation, check the required installation depth! Cut the installation opening, chamfer the bottom edge of the installation opening. Insert the housing from below and fix in place with a fast screw attachment.

Plasterboard / Installation from below: retrofitting with mineral fibreboard

Cut and chamfer the installation opening. Insert the housing from below and fix in place with a fast screw attachment. Mark opening for luminaires and cut. Smooth the joint or simply wallpaper the surface.

Transformer and luminaire installation

Push the transformer through...insert the closing cap...
Push the transformer through...insert the closing cap...
...install luminaires and fit decorative covering if used. Finished.
...install luminaires and fit decorative covering if used. Finished.

Dimensions / Form

Product depth:
90 mm
Installation opening (wall/ceiling) Ø:
86 mm

Assembly / Installation

Min. panel thickness:
7 mm
Panel thickness max.:
40 mm
Assembly type:
HW (drywall/lightweight construction), hollow ceiling

Safety / Properties

Special application:
Without
Instruction

ThermoX®

Assembly instructions

2.6 MB | 01/03/2021
ThermoX® individual front rings
Artikel-No. 9300-43
  • for retrofitting or as spare part
ThermoX® universal front ring
Artikel-No. 9300-93
  • for retrofitting or as spare part
  • Universal front ring
ThermoX® Decorative coverings
Artikel-No. 9301-11
E-No 920829119
  • metal with galvanised or powder coating
  • only for interiors
  • minimum diameter of the luminaire 79 mm with ceiling exit Ø 68 and 75 mm
  • Minimum diameter of luminaire covering 86 mm with ceiling exit Ø 82 mm
ThermoX® Decorative coverings
Artikel-No. 9301-13
E-No 920829319
  • metal with galvanised or powder coating
  • only for interiors
  • minimum diameter of the luminaire 79 mm with ceiling exit Ø 68 and 75 mm
  • Minimum diameter of luminaire covering 86 mm with ceiling exit Ø 82 mm
ThermoX® housing for low and high-voltage luminaires
Artikel-No. 9300-01
E-No 920849409
  • for halogen luminaires and pivoting LED luminaires
  • max. installation height for low-voltage luminaire 65 mm, HV luminaire 70 mm
  • Heat distortion resistant to 220°C
  • lamp wattage LV: max. 35 W with AL reflector / 20 W Cool-Beam
  • lamp wattage for HV luminaires max. 35 W with AL reflector (socket GU 10)
  • max. LED lamp output 6.6 W
  • Front can be used on both sides
ThermoX® housing for low and high-voltage luminaires
Artikel-No. 9300-02
E-No 920849419
  • for halogen luminaires and pivoting LED luminaires
  • max. installation height for low-voltage luminaire 65 mm, HV luminaire 70 mm
  • Heat distortion resistant to 220°C
  • lamp wattage LV: max. 35 W with AL reflector / 20 W Cool-Beam
  • lamp wattage for HV luminaires max. 35 W with AL reflector (socket GU 10)
  • max. LED lamp output 6.6 W
  • Front can be used on both sides