Ceiling lamp box

accessories

Insulated hook screw, 80 mm
Artikel-No. 1225-80
E-No 163612080
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 30 mm
Artikel-No. 1225-30
E-No 163612025
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 40 mm
Artikel-No. 1225-40
E-No 163612040
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 60 mm
Artikel-No. 1225-60
E-No 163612060
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 100 mm
Artikel-No. 1225-10
E-No 163612100
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 120 mm
Artikel-No. 1225-12
E-No 163612120
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 140 mm
Artikel-No. 1225-14
E-No 163612140
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg

tools

Universal opening cutter for plastics
Artikel-No. 1085-80
E-No 983228469
  • for manufacture of exact entry size
  • for low-voltage wiring of Ø 4 - 7.5 mm
  • for sheathed cabling up to 5 x 2.5 or 7 x 1.5
  • for cable NYY up to 5 x 2.5
  • for DIN EN conduits (flexible) with outer Ø of up to 20/25 mm
  • with 1/4" chuck size for battery-powered drills
Punch pliers
Artikel-No. 1286-33
E-No 983222016
  • for concrete construction installation
  • for exact entries for installation conduits
  • with plate ejector
  • punch bits exchangeable
Punch pliers
Artikel-No. 1286-34
E-No 983222026
  • for concrete construction installation
  • for exact entries for installation conduits
  • with plate ejector
  • punch bits exchangeable
Step drill
Artikel-No. 1284-32
E-No 983154009
  • for concrete construction installation
  • for manufacturing conduit entry openings
  • can be adapted for battery-powered drills

similar

Lamp box with outlet Ø 35 mm
Artikel-No. 1245-62
E-No 165921328
  • Conduit entry limitation to prevent the need to shorten the conduit inside
  • Meets the product standard EN 60670-21 (suspension load) with our hook bolts 1225-xx
  • Max. suspension load 50 N (5 kg)
Lamp box with outlet Ø 60 mm
Artikel-No. 1245-63
E-No 165921428
  • Conduit entry limitation to prevent the need to shorten the conduit inside
  • Meets the product standard EN 60670-21 (suspension load) with our hook bolts 1225-xx
  • Max. suspension load 50 N (5 kg)

Ceiling lamp box

Electric installations with KRFG tubes are one option of dealing with increasing cost pressure. Tube installation is simple, quick and safe.

KSK Technology - relating to flexible corrugated plastic conduits

KSK technology, KAISER conduit connection solution for quick, secure and variable conduit entries in concrete construction. Flexible corrugated plastic conduits with diameters of 20 or 25 mm can be inserted securely and accurately by hand. The KSK connection point can be opened with a single hammer blow - offering an integrated conduit insertion limitation, and protection against pull-out, for both conduit sizes.
KSK Technology - relating to flexible corrugated plastic conduits

M20/M25 combi-entry

M20 "KRFG" combi-entry
M20 "KRFG" combi-entry
M25 "KRFG" combi-entry
M25 "KRFG" combi-entry

Installation

The front part is simply nailed onto the wooden formwork.
The front part is simply nailed onto the wooden formwork.
The universal conduit entry is opened by striking with a hammer.
The universal conduit entry is opened by striking with a hammer.
Up to four conduits (M20 or M25) can now be inserted.
Up to four conduits (M20 or M25) can now be inserted.

Processing instructions

The screws used to attach the device...
The screws used to attach the device...
...can be easily screwed into the universal screw-on surface.
...can be easily screwed into the universal screw-on surface.
M20 combi-entry
M20 combi-entry
M25 combi-entry
M25 combi-entry

Dimensions / Form

Product Ø:
85 mm
Product depth:
105 mm

Connections / Entries

Number of entries:
4

Assembly / Installation

Assembly type:
BB (solid construction)

Safety / Properties

Special application:
on-site mixed concrete
Certificate
2.9 MB | 14/11/2024
Insulated hook screw, 80 mm
Artikel-No. 1225-80
E-No 163612080
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 30 mm
Artikel-No. 1225-30
E-No 163612025
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 40 mm
Artikel-No. 1225-40
E-No 163612040
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 60 mm
Artikel-No. 1225-60
E-No 163612060
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 100 mm
Artikel-No. 1225-10
E-No 163612100
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 120 mm
Artikel-No. 1225-12
E-No 163612120
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Insulated hook screw, 140 mm
Artikel-No. 1225-14
E-No 163612140
  • For retrofitting in ceiling boxes (EN 60670)
  • With self-forming thread, insulated
  • Proof voltage: 2500 V tested
  • Suspension load max. 5 kg
Universal opening cutter for plastics
Artikel-No. 1085-80
E-No 983228469
  • for manufacture of exact entry size
  • for low-voltage wiring of Ø 4 - 7.5 mm
  • for sheathed cabling up to 5 x 2.5 or 7 x 1.5
  • for cable NYY up to 5 x 2.5
  • for DIN EN conduits (flexible) with outer Ø of up to 20/25 mm
  • with 1/4" chuck size for battery-powered drills
Punch pliers
Artikel-No. 1286-33
E-No 983222016
  • for concrete construction installation
  • for exact entries for installation conduits
  • with plate ejector
  • punch bits exchangeable
Punch pliers
Artikel-No. 1286-34
E-No 983222026
  • for concrete construction installation
  • for exact entries for installation conduits
  • with plate ejector
  • punch bits exchangeable
Step drill
Artikel-No. 1284-32
E-No 983154009
  • for concrete construction installation
  • for manufacturing conduit entry openings
  • can be adapted for battery-powered drills
Lamp box with outlet Ø 35 mm
Artikel-No. 1245-62
E-No 165921328
  • Conduit entry limitation to prevent the need to shorten the conduit inside
  • Meets the product standard EN 60670-21 (suspension load) with our hook bolts 1225-xx
  • Max. suspension load 50 N (5 kg)
Lamp box with outlet Ø 60 mm
Artikel-No. 1245-63
E-No 165921428
  • Conduit entry limitation to prevent the need to shorten the conduit inside
  • Meets the product standard EN 60670-21 (suspension load) with our hook bolts 1225-xx
  • Max. suspension load 50 N (5 kg)