Cable sealing system LS 90, conduit sealing system RS 90

accessories

Sealing plug ECON® M16
Artikel-No. 1040-16
E-No 126573010
  • for sealing electrical installation conduits
  • ECON® technology for easy cable entry
  • permanently flexible plastic
Sealing plug ECON® M20
Artikel-No. 1040-20
E-No 126573020
  • for sealing electrical installation conduits
  • ECON® technology for easy cable entry
  • permanently flexible plastic
Sealing plug ECON® M25
Artikel-No. 1040-25
E-No 126573030
  • for sealing electrical installation conduits
  • ECON® technology for easy cable entry
  • permanently flexible plastic
Sealing identification tag DE/GB/FR/IT
Artikel-No. 9473-91
E-No 121819808
  • universal seal identification tag
  • for all KAISER sealings
  • can be filled out
  • in plastic, with 2 x 4.5 mm drill holes

Cable sealing system LS 90, conduit sealing system RS 90

Pipe and fire-retardant systems for safe closure of passages and entrances in fire-protection walls. The certified retardants are quick and easy to install and can even be superimposed on cables and pipes retrospectively (EI90). In addition, the cable sealing system can also be used as a wall outlet that enables the connection of electrical attachments.
  • Secure, visible, certified fire sealings
  • For wall feed-throughs and entries
  • Without filling and smoothing
  • Automatic sealing of the joints
  • For cables from Ø 5 - 15 mm
  • For conduits Ø 16 - 25 mm
  • For timber stud walls F30-F90 or EI30-EI90

Examples of applications for cable sealing system LS 90

Wall feed-through in plasterboard fire-protection wall.
Wall feed-through in plasterboard fire-protection wall.
Suitable for wall entry and wall outlet in dry construction fire protection wall.
Suitable for wall entry and wall outlet in dry construction fire protection wall.
Wall feed-through in a sand-lime brick fire-protection wall.
Wall feed-through in a sand-lime brick fire-protection wall.
Wall feed-through in concrete fire-protection wall.
Wall feed-through in concrete fire-protection wall.
Secure wall outlet up to EI90 for connecting electrical attachments...
Secure wall outlet up to EI90 for connecting electrical attachments...
...like motion detectors.
...like motion detectors.
Secure wall outlet up to EI90 for connecting electrical attachments...
Secure wall outlet up to EI90 for connecting electrical attachments...
...like wall lights.
...like wall lights.

Installation of cable sealing system LS 90 in cavity walls

Cut an installation opening Ø 20 mm using a cutter (e.g. KAISER hardened metal cutter Art. No. 1088-06) or drill.
Cut an installation opening Ø 20 mm using a cutter (e.g. KAISER hardened metal cutter Art. No. 1088-06) or drill.
To install, open the sealing sideways and slide it over the cable.
To install, open the sealing sideways and slide it over the cable.
Press both sides of the sealing into each opening.
Press both sides of the sealing into each opening.
The cable sealings can be arranged vertically or horizontally to form a group with a centre distance of 50 mm.
The cable sealings can be arranged vertically or horizontally to form a group with a centre distance of 50 mm.

Examples of applications for conduit sealing system RS 90

Wall feed-through in plasterboard fire-protection wall.
Wall feed-through in plasterboard fire-protection wall.
Ø 16 - 25 mm wall entry, in plasterboard fire-protection wall with Ø 25 mmconduit.
Ø 16 - 25 mm wall entry, in plasterboard fire-protection wall with Ø 25 mmconduit.
Wall feed-through in sand-lime brick fire-protection wall.
Wall feed-through in sand-lime brick fire-protection wall.
Wall feed-through in concrete fire-protection wall.
Wall feed-through in concrete fire-protection wall.

Installation of conduit sealing system RS 90 in cavity walls.

Cut a 35 mm installation opening using e.g. the KAISER cutter (Art. No. 1084-35).
Cut a 35 mm installation opening using e.g. the KAISER cutter (Art. No. 1084-35).
To install, open the sealing sideways and slide over the conduit.
To install, open the sealing sideways and slide over the conduit.
Press both sides of the sealing into each opening.
Press both sides of the sealing into each opening.
The conduit sealings can be arranged vertically or horizontally to form a group with a centre distance of 50 mm.
The conduit sealings can be arranged vertically or horizontally to form a group with a centre distance of 50 mm.

Installation of conduit sealing system RS 90 in solid walls

Make an installation opening using a Ø 32 mm drill.
Make an installation opening using a Ø 32 mm drill.
Remove the strap for mounting in masonry (only when installing a conduit sealing in a masonry wall).
Remove the strap for mounting in masonry (only when installing a conduit sealing in a masonry wall).
After installing the sealing, apply the identification tag.
After installing the sealing, apply the identification tag.
The sealings can be used in masonry and concrete walls.
The sealings can be used in masonry and concrete walls.

Dimensions / Form

Product Ø:
32 mm
Installation opening (wall/ceiling) Ø:
32 mm

Connections / Entries

For conduit Ø:
16 mm, 25 mm

Assembly / Installation

Wall thickness min.:
100 mm

Safety / Properties

Sound insulation walls up to:
76
Special application:
Fire protection
Sound insulation:
Yes

Approvals / Certifications

fire resistance class:
EI 30, EI 90
DIBT approval:
Z-19.53-2531
European Technical Assessment approval:
ETA-17-0449
Sealing plug ECON® M16
Artikel-No. 1040-16
E-No 126573010
  • for sealing electrical installation conduits
  • ECON® technology for easy cable entry
  • permanently flexible plastic
Sealing plug ECON® M20
Artikel-No. 1040-20
E-No 126573020
  • for sealing electrical installation conduits
  • ECON® technology for easy cable entry
  • permanently flexible plastic
Sealing plug ECON® M25
Artikel-No. 1040-25
E-No 126573030
  • for sealing electrical installation conduits
  • ECON® technology for easy cable entry
  • permanently flexible plastic
Sealing identification tag DE/GB/FR/IT
Artikel-No. 9473-91
E-No 121819808
  • universal seal identification tag
  • for all KAISER sealings
  • can be filled out
  • in plastic, with 2 x 4.5 mm drill holes