Consolidation Box

accessories

Mounting plate MK for cable trays
Article number: AT2215
  • Compact mounting plate for quick click-mounting on the side of the cable tray.
  • Suitable for all common cable duct brands.
  • Can also be fitted underneath some cable ducts.
  • To be used in combination with AK2-S L/D data tray (art. no. AT1963) and AK2 tray (art. no. AT2292).
  • Can also be used in combination with standard AK1 and AK2 cable boxes (art. no. AT2280 and art. no. AT2290).
  • Suitable for cable support systems from well-known manufacturers
Data cable entry
Article number: AT1966
  • The slide-in data lead-in, made of soft rubber, is suitable for the lead-in of a maximum of 3 data cables (UTP, FTP, STP etc.).
  • Provides grip on the cable sheath without untwisting the conductor pairs or in any other way influencing the data transmission.
  • for AK2 housing
Blanking plug
Article number: AT2257
  • Provides closure of lead-ins on AK2-S junction boxes that have been broken out but will not be used.
  • Can be punctured to allow lead-in of thin cables < Ø 10 mm.
  • for AK2 housing

Consolidation Box

The Consolidation Box from Attema makes it possible to install ICT cabling in a flexible manner, because the installation is divided into two steps. The largest portion of the work takes place during the rough construction, at the same time as the other cabling is installed in the building. As a result, you only have to install a small portion of the ICT cabling during the finishing phase. The Consolidation Box complies with the installation standards of EIA/TIA 568A/B, ISO 11801 and NEN-EN 50173.
ETIM Product Classification:
Box/housing for surface mounting on the wall/ceiling
Model: Junction box
Equipped with: Other
Max. conductor cross section:
Number of poles:
Number of clamp positions per pole:
Shape: Rectangular
Mounting method: Universal
Mounting in the soil: No
Mounting under water: No
Suitable for tube diameter:
Number of inlets: 10
Inlet from the rear: No
Length: 120 mm
Width: 95 mm
Depth: 40 mm
Diameter:
Number of cable glands included:
Connectable: No
Type of housing feed-through: Preembossing
With strain relief:
Material: Plastic
Halogen free: No
Surface protection: Untreated
Colour: Grey
RAL-number (similar):
Degree of protection (IP): IP20
Degree of protection (NEMA):
Cover model: None
Outgoing connections with connectors for plug-in building installation:
Transparent cover: No
Castable: No
Cover attachment: Snapped on
Casting compound included: No
Sealable: No
Rated insulation voltage Ui: 690 V
Circuit integrity: None
With screening: No
Weatherproof: No
Working temperature: -40 - 70 °C
Explosion-tested version: No
Suitable for Ex-zone gas: None
Suitable for Ex-zone dust: None

Dimensions / Form

Product length:
120 mm
Product width:
95 mm
Product depth:
40 mm

Connections / Entries

Number of entries:
10

Installationdetails

Fastening type (other):
Screw holes

Safety / Properties

Halogen-free:
Yes

Certificates & Quality marks

VDE:
Yes

Storage / Installation / Operation

Minimum operating temperature:
-40 °C
Maximum operating temperature:
70 °C
Mounting plate MK for cable trays
Article number: AT2215
  • Compact mounting plate for quick click-mounting on the side of the cable tray.
  • Suitable for all common cable duct brands.
  • Can also be fitted underneath some cable ducts.
  • To be used in combination with AK2-S L/D data tray (art. no. AT1963) and AK2 tray (art. no. AT2292).
  • Can also be used in combination with standard AK1 and AK2 cable boxes (art. no. AT2280 and art. no. AT2290).
  • Suitable for cable support systems from well-known manufacturers
Data cable entry
Article number: AT1966
  • The slide-in data lead-in, made of soft rubber, is suitable for the lead-in of a maximum of 3 data cables (UTP, FTP, STP etc.).
  • Provides grip on the cable sheath without untwisting the conductor pairs or in any other way influencing the data transmission.
  • for AK2 housing
Blanking plug
Article number: AT2257
  • Provides closure of lead-ins on AK2-S junction boxes that have been broken out but will not be used.
  • Can be punctured to allow lead-in of thin cables < Ø 10 mm.
  • for AK2 housing