Fibre optic termination point (Gf-AP)

Fibre optic termination point (Gf-AP)

The fibre optic termination point is the end point of the fibre optic line as a transition to the building network. It serves as mechanical protection for the splice connection with a compact fibre termination unit for distributing the fibres to the couplings and residential units. The Gf-AP 16 fibre optic termination point can also be used as a building or floor distributor. It can be used as a distribution point for up to 16 residential units per floor. It can be used as a splice-patch distributor with couplings or as a splice-splice distributor. Thanks to its IK08 protection and attractive design, it adapts in with its surroundings.
  • Distribution of the incoming cable to several residential units
  • Connection for up to 16 residential units
  • Locking via Torx screw or profile half cylinder
  • Labelling panels.
  • Strain relief for tubes and cables
  • Compact design
  • Separation of the provider cable and customer cable areas using separate covers.

Application examples

ETIM Product Classification:
Distributor for telecommunication
Model: Wall-mounted distributor
Mounting method: Surface mounted
With connecting lugs: No
Max. number of dual cores:
Mounting dimension (standardised): Other
110-compatible: No
LSA: No
SID:
Material: Plastic
Degree of protection (IP): IP54
Degree of protection (NEMA):
Colour: White
Height: 230 mm
Width: 200 mm
Depth: 70 mm
Number of mountable connection strips: 16
DIN-compatible: No
Compatible with Grade2TV according to XP-C 90-483: No
Compatible with Grade3TV according to XP-C 90-483: No

Dimensions / Form

Product length:
230 mm
Product width:
200 mm
Product depth:
70 mm

Safety / Properties

Halogen-free:
Yes

Features

Network level:
3 / 4
Splice cassette quantity:
2
Number of fibres (max.):
32
Microtube size (max.):
12 mm

Certificates & Quality marks

Protection class:
IP54

Storage / Installation / Operation

Minimum storage temperature:
-10 °C
Maximum storage temperature:
60 °C
Minimum installation temperature:
-10 °C
Installation temperature max.:
60 °C
Minimum operating temperature:
-20 °C
Maximum operating temperature:
60 °C
Technical information

Datasheet Building Entry Point Gf-AP 4231035-4231048 V1.0