AGRO combination conduit glands Progress® nickel-plated brass increased saftey Ex e II

Short entry thread metric

Approval type: Progress MS Kombi EX

  • One-piece sealing insert
  • not overall length insulated
- Progress MS Kombi EX
- Einteiliger Dichteinsatz
- nicht durchgehend isolierend
- Progress MS Kombi EMC
- Einteiliger Dichteinsatz
- nicht durchgehend isolierend

Variants (21)

Thread M12x1.5 M16x1.5 M16x1.5 M16x1.5 M20x1.5 M20x1.5 M20x1.5 M20x1.5 M20x1.5 M20x1.5 M20x1.5 M20x1.5 M25x1.5 M25x1.5 M25x1.5 M25x1.5 M25x1.5 M32x1.5 M40x1.5 M50x1.5 M63x1.5
Min. clamping range 4 mm 4.5 mm 6 mm 8.5 mm 6.5 mm 9.5 mm 6.5 mm 9.5 mm 12 mm 6.5 mm 9.5 mm 12 mm 10.5 mm 13 mm 10.5 mm 13 mm 17 mm 19 mm 25 mm 35 mm 44 mm
Max. clamping range 6.5 mm 6 mm 8 mm 10.5 mm 8 mm 11 mm 8 mm 11 mm 15 mm 8 mm 11 mm 15 mm 12.5 mm 16 mm 12.5 mm 16 mm 20.5 mm 21 mm 28.5 mm 37 mm 46 mm
Spanner size 15/17 mm 18/21 mm 18/21 mm 18/21 mm 24/25 mm 24/25 mm 24/27 mm 24/27 mm 24/27 mm 24/29 mm 24/29 mm 24/29 mm 30/29 mm 30/29 mm 30/36 mm 30/36 mm 30/36 mm 36/36 mm 45/45 mm 55/54 mm 70/66 mm
Thread type metric metric metric metric metric metric metric metric metric metric metric metric metric metric metric metric metric metric metric metric metric
Thread length short short short short short short short short short short short short short short short short short short short short short
clamp technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology Compression technology
Protection class IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66 IP68, IP66
Explosion-proof design Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
EX zone Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22 Gas 1 and 2 - Dust 21 and 22
Gas II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb II 2G Ex eb IIC Gb
Dust II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db II 2D Ex tb IIIC Db
Test standard IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0 IEC EN 60079-31, IEC EN 60079-7, IEC EN 60079-0
Artikel-No. EX1700.12.10.065 EX1700.17.14.060 EX1700.17.14.080 EX1700.17.14.105 EX1700.20.17.080 EX1700.20.17.110 EX1700.20.19.080 EX1700.20.19.110 EX1700.20.19.150 EX1700.20.21.080 EX1700.20.21.110 EX1700.20.21.150 EX1700.25.21.125 EX1700.25.21.160 EX1700.25.27.125 EX1700.25.27.160 EX1700.25.27.205 EX1700.32.27.210 EX1700.40.36.285 EX1700.50.45.370 EX1700.63.56.460
Packaging / Shipping - / 50 - / 50 - / 50 - / 50 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 25 - / 10 - / 10 - / 5