Filter
Support connector
Artikel-No.
9060-68
- For fully insulated through-wiring in combinations
- Smokeproof
- for Art. Nos. 9463-03, 9464-03
HWD 68+ one-gang box
Artikel-No.
9463-03
- For F30-F90 or EI30-EI90, F30-B to F90-B fire-protection walls
- also for directly opposing installation
- from wall thicknesses of 100 mm
- can be combined with each other and with the one-gang junction box
HWD 68+ one-gang junction box
Artikel-No.
9464-03
- For F30-F90 or EI30-EI90, F30-B to F90-B fire-protection walls
- also for directly opposing installation
- from wall thicknesses of 125 mm
- combinable with each other and with the one-gang box
Fire protection PROTECT® one-gang junction box for solid wood
Artikel-No.
9464-05
- For F30-B to F120-B solid wood elements
- Mounting with rib fixing
- Cable entry enables tolerance compensation of the cable route
- Also for directly opposing installation
- Preserves the sound insulation properties of the solid wood elements
FlamoX® fire-protection putty
Artikel-No.
9400-05
- Building material forming an insulating layer
- for filling joints as well as bonding board materials
- Working time 30 mins.
- Can be stored up to 12 months
HWD 90 one-gang box
Artikel-No.
9463-01
- For F30-F120 or EI30-EI120 and F30-B / F60-B fire-protection walls
- Also for I30 - I90 installation shafts / installation ducts
- also for F30-B - F60-B timber frame or timber panel construction walls
HWD 90 one-gang junction box
Artikel-No.
9464-01
- For F30-F120 or EI30-EI120 and F30-B / F60-B fire-protection walls
- Also for I30 - I90 installation shafts / installation ducts
- also for F30-B - F60-B timber frame or timber panel construction walls
Electronics box HWD 90
Artikel-No.
9462-94
- For cables and conduits up to Ø 25 mm
- Also for use as a double box
- For fire-protection walls F30-F120 or EI30-EI20
- minimum wall thickness 100 mm
- For equipment inserts and electronic components
- Tunnel twin-chamber box with enclosed separator wall and cover that can be wallpapered over.
- Can be combined with each other and also with HWD 90 one-gang junction boxes
Fire-protection cover HWD 30-120
Artikel-No.
1184-94
- For one-gang boxes/one-gang junction boxes and ceiling boxes HWD 90, HWD 30, HWD 68+, solid wood box PROTECT® and B15 PROTECT®
- Fire resistance class in accordance with ceiling or wall protection (F30-F120 and EI30-EI120)
- F30-F120 and EI30-EI120 function in conjunction with the one-gang box/one-gang junction box HWD 90
- F30 and EI30 function in conjunction with ceiling junction box HWD 30
- F30-F60 and EI30-EI60 function in connection with one-gang/one gang junction box HWD 68+
Ceiling box HWD 30
Artikel-No.
9463-50
- for fire protection ceilings F30-F90 or EI30-EI90
- For F30 (EI30) non-insulated fire-protection ceilings
- For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
- for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100
Ceiling junction box HWD 30
Artikel-No.
9464-50
- for fire protection ceilings F30-F90 or EI30-EI90
- For F30 (EI30) non-insulated fire-protection ceilings
- For F60 (EI60) fire-protection ceilings backed with mineral insulation materials in compliance with EN 13501 part 1
- for F90 (EI90) fire-protection ceilings with Rockwool/Termarock 100
One-gang box HWD B15 for thin boarding 40 mm
Artikel-No.
9461-14
- for shipbuilding walls of category B15
HWD B15 one-gang junction box for thin boarding
Artikel-No.
9464-14
- for shipbuilding walls of category B15