The extra-large junction boxes are designed as a modular system: two alternative base units are available - one with a smaller and one with a greater depth - and the electrician can choose from a range of matching extension pieces (for extra depth), plastering covers, screwed-on covers, waterproof covers and universal covers.
  • Quick and secure installation using pre-inserted nails
  • Increased robustness
  • Conduit markings for drilling diameters
  • Stackable

Examples of use

According to DIN 18015-1, pull-wire boxes are required for conduit sections of more than 15 m in length or when more than 2 bends are present.
According to DIN 18015-1, pull-wire boxes are required for conduit sections of more than 15 m in length or when more than 2 bends are present.
KAISER wire-pull casings provide maximum room for the pulling and retrofitting of cables.
KAISER wire-pull casings provide maximum room for the pulling and retrofitting of cables.
In case of sub-ceiling insulation, the wire-pull casing can be extended via intermediate frames
In case of sub-ceiling insulation, the wire-pull casing can be extended via intermediate frames
Also suitable for wall mounting - to be fastened to the reinforcement via Prefix® installation technology.
Also suitable for wall mounting - to be fastened to the reinforcement via Prefix® installation technology.

Installation tips

Fixing in place on the ceiling formwork is done using eight pre-inserted nails. The nail channels have a predetermined breaking point, so that the nails will be removed together with the formwork.
Fixing in place on the ceiling formwork is done using eight pre-inserted nails. The nail channels have a predetermined breaking point, so that the nails will be removed together with the formwork.
The conduit entries can be easily opened using a step drill or a hammer and screwdriver.
The conduit entries can be easily opened using a step drill or a hammer and screwdriver.
If multiple different conduits are to be connected, the side walls can be removed using a hammer.
If multiple different conduits are to be connected, the side walls can be removed using a hammer.
Additional lugs facilitate secure fixing to the reinforcement bars using tying wire.
Additional lugs facilitate secure fixing to the reinforcement bars using tying wire.

Dimensions / Form

Product length:
246 mm
Product width:
176 mm
Product depth:
45 mm

Assembly / Installation

Assembly type:
BB (solid construction)

Safety / Properties

Special application:
on-site mixed concrete
Certificate

9916.68