recommendations

Flush mounting one-gang junction box, Depth 66 mm
Artikel-No. 1555-04
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
Flush mounting one-gang junction box, Depth 66 mm
Artikel-No. 1556-04
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
One-gang junction box ECON® 15, air-tight, Depth 66 mm
Artikel-No. 1555-21
  • Air-tight design with ECON® sealing membranes
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
Electronics box with separator wall
Artikel-No. 1068-02
  • Twin-chamber box (with separator wall)
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
Electronics box ECON®, airtight
Artikel-No. 1068-21
  • Separator wall for electrical circuit separation
  • Air-tight design with sealing membranes
Two-gang junction box ECON®, air-tight
Artikel-No. 1656-21
  • Air-tight design with sealing membranes

Assembly and connection option with tunnel connector

Remove the break-out openings under the support connector on both one-gang junction boxes.
Remove the break-out openings under the support connector on both one-gang junction boxes.
Plug the one-gang junction boxes together and insert the tunnel connector (item no. 1159-36) between the two one-gang junction boxes...
Plug the one-gang junction boxes together and insert the tunnel connector (item no. 1159-36) between the two one-gang junction boxes...
...then plug the support connector in from below for fully insulated through-wiring in the floor area.
...then plug the support connector in from below for fully insulated through-wiring in the floor area.
Cable entry through the tunnel connector. For installation with low-seated installation accessories.
Cable entry through the tunnel connector. For installation with low-seated installation accessories.

Assembly and connection option with tunnel connector

Plug the one-gang junction boxes together...
Plug the one-gang junction boxes together...
...insert the tunnel connector (item no. 1159-36) between the two one-gang junction boxes...
...insert the tunnel connector (item no. 1159-36) between the two one-gang junction boxes...
...and then plug the support connector in from below for fully insulated through-wiring in the floor area.
...and then plug the support connector in from below for fully insulated through-wiring in the floor area.
Cable entry through the tunnel connector. For installation with low-seated installation accessories.
Cable entry through the tunnel connector. For installation with low-seated installation accessories.

Assembly / Installation

Assembly type:
UP (solid construction)
The heart of every installation. - The KAISER box.
Flyer

The heart of every installation. - The KAISER box.

Designed by craftsmen, made by KAISER!

Flush mounting one-gang junction box, Depth 66 mm
Artikel-No. 1555-04
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
Flush mounting one-gang junction box, Depth 66 mm
Artikel-No. 1556-04
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
One-gang junction box ECON® 15, air-tight, Depth 66 mm
Artikel-No. 1555-21
  • Air-tight design with ECON® sealing membranes
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
Electronics box with separator wall
Artikel-No. 1068-02
  • Twin-chamber box (with separator wall)
  • dimensions in accordance with German DIN 49073
  • For 20/25 mm conduits and cables
Electronics box ECON®, airtight
Artikel-No. 1068-21
  • Separator wall for electrical circuit separation
  • Air-tight design with sealing membranes
Two-gang junction box ECON®, air-tight
Artikel-No. 1656-21
  • Air-tight design with sealing membranes